Emergency Lighting Solutions KVD188B-EM03 Suitable for 5W to 70W LED lamps

KVD188B-EM03
Emergency Light Ballast Driver Battery Kits apply in Led constant current lighting luminaires’ normal lighting or emergency lighting mode, also can be only for emergency lighting purposes.

Emergency lighting solutions provided “charging”, and “discharging” functions, and use intelligent IC controlling circuits, according to be high exchange efficiency and smaller battery capacity.

Internal Li-ion battery, compatible with dimming or non-dimming led luminaire, external installation, emergency supply will be standing and charging by when AC grid electricity supply in normal, will be going to self-maintenance when fully charged, according to longer the battery’s lifespan

The emergency driver will be back up the lighting luminaires within 3 seconds when AC grid electricity stopped, to be sure the light can be working for 1 to 3hrs normally.

Model: KVD188B-EM03 LED emergency conversion kit, built-in one 18650 2200mah lithium-ion battery, this emergency conversion kit of ours, can power lights with maximum 70W external LED drivers,
So it is a perfect LED emergency conversion kit for LED panel lights, ceiling lights, downlight, and tri-proof lights.
The maximum driving current of LED lamps cannot exceed 2.5A. the maximum DC voltage of the lamp board does not exceed 95V。

3W LED Emergency Lighting Solutions specifications:
1. Emergency Power: 3W
2. Lighting Power: 5W-70W
3. Conversion Efficiency: ≥95%
4. Emergency duration time: 1.5 hours or 2 hours or 3 hours
5. Input Voltage: AC100-277V
6. Output Voltage: DC20-85V
7. Charging Time: 24 hours
8. Working Lifetime(Hour)30000
9. 2years warranty.
10. Best quality and factory price

LED Emergency Lighting Solutions Features

Built-in a 18650 legion battery, safe and convenient to use.
Energy-saving emergency driver conversion/inverter solution, power the LED light at a low-cost power.
Automatically turns on LED lighting when there is a main power failure.
The LED emergency driver battery backup with overcharge and discharge protection, output short protection, overload protection, over-temperature protection
With indicator: Green=Main Circuit, Red=Charging.
Each led emergency driver is passed a 100% full power load aging test, CE Rosh certified.
Working Environment Attention

Working & storage temperature: -10℃–+45℃(Standard temperature 28℃)
To ensure a longer lifetime, an LED emergency battery is needed to be charged and discharged every 3 months.
If stored longer than 3 months in a warehouse, an emergency battery is needed to be charged and discharged every 3 months.
Our emergency batteries can be charged/discharged 500 cycles if used in the right way.
Please make sure the wire connection is correct before switch on for a long time usage

Contact